Heart, Lung and Circulation
Volume 15, Issue 1 , Pages 12-17, February 2006

Transcatheter Closure of Muscular Ventricular Septal Defect Using the Amplatzer Devices

Institut Jantung Negara, Kuala Lumpur, Malaysia, 145 Jl. Tun Razak, 50400 Kuala Lumpur, Malaysia

Technique

From November 1997 to June 2002, percutaneous transcatheter closure of muscular ventricular septal defects was attempted in seven patients. Four patients had single and three had multiple defects. Surgical closure was performed in two patients in an attempt to close a perimembranous defect, leaving behind a large apical muscular defect, which was successfully closed using a device in one patient, whilst the second patient succumbed to septicemia/endocarditis 3 weeks after failure of device implantation. One patient had previous pulmonary artery banding and in another intraoperative placement of two Clamshell devices followed by additional transcatheter closure using Gianturco coils in two different sessions was performed.

Results

Transcatheter closure of ventricular septal defect was successful in six patients. Three patients underwent closure of their ventricular septal defects using the Amplatzer Septal Occluder and in the remaining three patients. Amplatzer Muscular Ventricular Septal Defect Occluder was used. The median age was 15 months (range 14 months to 10 years) and the median weight was 7.8kg (range 7–16kg). The devices were deployed antegradely in all patients. Immediate complete closure was obtained in three patients while two patients had small and one had a large residual following the procedure. The later was due to another multiple muscular septal defect. Transient heart block occurred in one patient during the procedure and another patient developed heart block on day 3 post-procedure. The latter required temporary pacemaker. During the follow up, one patient who had residual multiple muscular defects underwent a successful redo transcatheter closure using two Amplatzer Muscular Ventricular Septal Occluder devices.

Conclusions

We conclude that transcatheter closure of muscular ventricular septal defect using Amplatzer devices is feasible and effective.

Keywords: Transcatheter closure, Ventricular septal defect, Amplatzer devices

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1443-9506(05)00032-6

doi:10.1016/j.hlc.2005.02.005

Heart, Lung and Circulation
Volume 15, Issue 1 , Pages 12-17, February 2006