Advertisement
Heart, Lung and Circulation
Original Article| Volume 23, ISSUE 3, P229-233, March 2014

Hepatic and Renal Function with Successful Long-term Support on a Continuous Flow Left Ventricular Assist Device

Published:September 03, 2013DOI:https://doi.org/10.1016/j.hlc.2013.07.021

      Introduction

      Data regarding the long-term clinical effects of a continuous flow left ventricular assist device (CF-LVAD) on hepato-renal function is limited. Hence our aim was to assess changes in hepato-renal function over a one-year period in patients supported on a CF-LVAD.

      Methods

      During the study period 126 patients underwent CF-LVAD implant. Changes in hepato-renal laboratory parameters were studied in 61/126 patients successfully supported on a CF-LVAD for period of one year. A separate cohort of a high-risk group (HCrB) of patients (56/126) with a serum creat > 1.9 mg/dL (168 μmol/L) (75th percentile) or a serum bil > 1.5 mg/dL (25.65 μmol/L) (75th percentile) was created. Changes in serum creatinine and bilirubin were analysed at regular intervals for this group along with the need for renal replacement therapy.

      Results

      Baseline creatinine and blood urea nitrogen (BUN) for the entire cohort was 1.4[1.2,1.9 mg/dL] [123.7(106,168) μmol/L) and 27[20,39.5 mg/dL] [9.6(7.1,14.1) mmol/L] respectively. After an initial reduction at the end of one month [1(0.8,1.2) mg/dL; 88(70,105) μmol/L] (p < 0.0001), a gradual increase was noted over the study period to reach (1.25[1.1,1.5] mg/dL; 106(97.2,132.6) μmol/L] (p = 0.0003). The serum bilirubin normalised from a [1(0.7,1.55) mg/dL] [17(18.8,25.7) μmol/L) to 0.9(0.6,1.2) mg/dL [15.4(10.2,20.5) μmol/L] (p = 0.0005) and continued to decline over one year. Improvement in the synthetic function of the liver was demonstrated by a rise in the serum albumin levels to reach 4.3[4.1,4.5] [43(41,45) gm/L] at the end of one year (p < 0.0001).
      The baseline serum creatinine and bilirubin for the high-risk cohort (HCrB) was 1.9(1.3,2.4) mg/dL [168(115,212) μmol/L] and 1.7(1.00,2.4) mg/dL [29(17.1,68.4) μmol/L] respectively. The high-risk cohort (HCrB) demonstrated a trend towards higher 30-day mortality (p = 0.06). While the need for temporary renal replacement therapy was higher in this cohort (16% vs. 4%; p = 0.03), only 3% need it permanently. A significant reduction in creatinine was apparent at the end of one month [1.1(0.8,1.4) mg/dL; 97(70.7,123.7) μmol/L] (p < 0.0001) and then remained stable at [1.3(1.1,1.5) mg/dL; 115(97,132.6) μmol/L]. Bilirubin demonstrated a 30% decline over one month and then remained low at [0.7(0.5,0.8) mg/dL; 62(44,70) μmol/L] p = 0.0005 compared to the pre-operative baseline.

      Conclusion

      Hepato-renal function demonstrates early improvement and then remains stable in the majority of patients on continuous flow left ventricular assist device support for one year. High-risk patients demonstrate a higher 30-day mortality and temporary need for renal replacement therapy. Yet even in this cohort, improvement is present over a period of one year on the device, with a minimal need for permanent haemodialysis.

      Keywords

      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Heart, Lung and Circulation
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Park S.J.
        • Milano C.A.
        • Tatooles A.J.
        • Rogers J.G.
        • Adamson R.M.
        • Steidley D.E.
        • et al.
        Outcomes in advanced heart failure patients with left ventricular assist devices for destination therapy.
        Circ Heart Fail. 2012; 5: 241-248
        • Letsou G.V.
        • Myers T.J.
        • Gregoric I.D.
        • Delgado R.
        • Shah N.
        • Robertson K.
        • et al.
        Continuous axial-flow left ventricular assist device (Jarvik 2000) maintains kidney and liver perfusion for up to 6 months.
        Ann Thorac Surg. 2003; 76: 1167-1170
        • Russell S.D.
        • Rogers J.G.
        • Milano C.A.
        • Dyke D.B.
        • Pagani F.D.
        • Aranda J.M.
        • et al.
        Renal and hepatic function improve in advanced heart failure patients during continuous-flow support with the HeartMate II left ventricular assist device.
        Circulation. 2009; 120: 2352-2357
        • Matthews J.C.
        • Pagani F.D.
        • Haft J.W.
        • Koelling T.M.
        • Naftel D.C.
        • Aaronson K.D.
        Model for end-stage liver disease score predicts left ventricular assist device operative transfusion requirements, morbidity, and mortality.
        Circulation. 2010; 121: 214-220
        • Rose E.A.
        • Gelijns A.C.
        • Moskowitz A.J.
        • Heitjan D.F.
        • Stevenson L.W.
        • Dembitsky W.
        • et al.
        Long-term use of a left ventricular assist device for end-stage heart failure.
        N Engl J Med. 2001; 345: 1435-1443
        • Kirklin J.K.
        • Naftel D.C.
        • Kormos R.L.
        • Stevenson L.W.
        • Pagani F.D.
        • Miller M.A.
        • et al.
        Second INTERMACS annual report: more than 1000 primary left ventricular assist device implants.
        J Heart Lung Transplant. 2010; 29: 1-10
        • Kihara S.
        • Litwak K.N.
        • Nichols L.
        • Litwak P.
        • Kameneva M.V.
        • Wu Z.
        • et al.
        Smooth muscle cell hypertrophy of renal cortex arteries with chronic continuous flow left ventricular assist.
        Ann Thorac Surg. 2003; 75 ([discussion 83]): 178-183
        • Saito S.
        • Westaby S.
        • Piggot D.
        • Dudnikov S.
        • Robson D.
        • Catarino P.A.
        • et al.
        End-organ function during chronic nonpulsatile circulation.
        Ann Thorac Surg. 2002; 74: 1080-1085
        • Radovancevic B.
        • Vrtovec B.
        • de Kort E.
        • Radovancevic R.
        • Gregoric I.D.
        • Frazier O.H.
        End-organ function in patients on long-term circulatory support with continuous- or pulsatile-flow assist devices.
        J Heart Lung Transplant. 2007; 26: 815-818
        • Sandner S.E.
        • Zimpfer D.
        • Zrunek P.
        • Dunkler D.
        • Schima H.
        • Rajek A.
        • et al.
        Renal function after implantation of continuous versus pulsatile flow left ventricular assist devices.
        J Heart Lung Transplant. 2008; 27: 469-473
        • Hasin T.
        • Topilsky Y.
        • Schirger J.A.
        • Li Z.
        • Zhao Y.
        • Boilson B.A.
        • et al.
        Changes in renal function after implantation of continuous-flow left ventricular assist devices.
        J Am Coll Cardiol. 2012; 59: 26-36
        • Wadia Y.
        • Etheridge W.
        • Smart F.
        • Wood R.P.
        • Frazier O.H.
        Pathophysiology of hepatic dysfunction and intrahepatic cholestasis in heart failure and after left ventricular assist device support.
        J Heart Lung Transplant. 2005; 24: 361-370