Current Clinical Practice in Patients With Cardiac Implantable Electronic Devices (CIED) Undergoing Radiotherapy (RT)

Published:November 26, 2021DOI:https://doi.org/10.1016/j.hlc.2021.10.020
      Patients with cardiac implantable electronic devices (CIED) undergoing radiotherapy (RT) becoming more common due to ageing of the population. With newer CIEDs implementing the complementary metal-oxide semiconductor (CMOS) technology which allows the miniaturisation of CIED, it is also more susceptible to RT. Effects of RT on CIED ranges from device interference, device operational/memory errors to permanent damage. These malfunctions can cause life threatening clinical effects. Cumulative dose is not the only component of RT that causes CIED malfunction, as neutron use and dose rate effect also affects CIEDs. The management of this patient cohort in clinical practice is inconsistent due to lack of a consistent guideline from manufacturers and physician specialty societies. Our review will focus on the current clinical practice and the recent updated guidelines of managing patients with CIED undergoing RT. We aim to simplify the evidence and provide a simple and easy to use guide based on the recent guidelines.

      Keywords

      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Heart, Lung and Circulation
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Zhan C.
        • Baine W.B.
        • Sedrakyan A.
        • Steiner C.
        Cardiac device implantation in the United States from 1997 through 2004: a population-based analysis.
        J Gen Intern Med. 2008; 23: 13-19
        • Bradshaw P.J.
        • Stobie P.
        • Knuiman M.W.
        • Briffa T.G.
        • Hobbs M.S.
        Trends in the incidence and prevalence of cardiac pacemaker insertions in an ageing population.
        Open Heart. 2014; 1: e000177
        • Boriani G.
        • Berti E.
        • Belotti L.M.B.
        • Biffi M.
        • Carboni A.
        • Bandini A.
        • et al.
        Cardiac resynchronization therapy: implant rates, temporal trends and relationships with heart failure epidemiology.
        J Cardiovasc Med. 2014; 15: 147-154
        • Stone K.R.
        • McPherson C.A.
        Assessment and management of patients with pacemakers and implantable cardioverter defibrillators.
        Crit Care Med. 2004; 32: S155-S165
        • Tondato F.
        • Ng D.W.
        • Srivathsan K.
        • Altemose G.T.
        • Halyard M.Y.
        • Scott L.R.
        Radiotherapy-induced pacemaker and implantable cardioverter defibrillator malfunction.
        Expert Rev Med Devices. 2009; 6: 243-249
        • Torre L.A.
        • Bray F.
        • Siegel R.L.
        • Ferlay J.
        • Lortet-Tieulent J.
        • Jemal A.
        Global cancer statistics, 2012.
        CA Cancer J Clin. 2015; 65: 87-108
        • Nemec J.
        Runaway implantable defibrillator—a rare complication of radiation therapy.
        Pacing Clin Electrophysiol. 2007; 30: 716-718
        • Zweng A.
        • Schuster R.
        • Hawlicek R.
        • Weber H.S.
        Life-threatening pacemaker dysfunction associated with therapeutic radiation: a case report.
        Angiology. 2009; 60: 509-512
        • Zaremba T.
        • Jakobsen A.R.
        • Thøgersen A.M.
        • Oddershede L.
        • Riahi S.
        The effect of radiotherapy beam energy on modern cardiac devices: an in vitro study.
        Europace. 2014; 16: 612-616
        • Marbach J.R.
        • Sontag M.R.
        • Van Dyk J.
        • Wolbarst A.B.
        Management of radiation oncology patients with implanted cardiac pacemakers: report of AAPM Task Group No. 34. American Association of Physicists in Medicine.
        Med Phys. 1994; 21: 85-90
        • Miften M.
        • Mihailidis D.
        • Kry S.F.
        • Reft C.
        • Esquivel C.
        • Farr J.
        • et al.
        Management of radiotherapy patients with implanted cardiac pacemakers and defibrillators: a report of the AAPM TG-203.
        Med Phys. 2019; 46: e757-e788
        • Hudson F.
        • Coulshed D.
        • D'Souza E.
        • Baker C.
        Effect of radiation therapy on the latest generation of pacemakers and implantable cardioverter defibrillators: a systematic review.
        J Med Imaging Radiat Oncol. 2010; 54: 53-61
      1. Medtronic. Standard Letter 17 April 2017. https://wwwp.medtronic.com/crs-upload/letters/51/51_CQES-Standard_Letter_Radiotherapy-Rev3-2017Apr.pdf. [accessed 17.7.21]

      2. Jude S. Effects of therapeutic radiation on St. Jude medical implantable cardiac rhythm devices. 2013. (Technical Services Rev 11/13).

      3. Boston Scientific. Therapeutic radiation and implantable device systems. REvision 002-1675 2013. https://www.bostonscientific.com/content/dam/bostonscientific/quality/education-resources/english/ACL_Therapeutic_Radiation_20120925.pdf. [accessed 17.7.21]

      4. Biotronik. Radiation therapy and BIOTRONIK CRM devices - pacemakers (IPG), defibrillators (ICD) and CRT-devices. 2011. https://www.biotronik.com/en-us/products. [accessed 17.7.21]

        • Körner P.
        • Ehrmann K.
        • Hartmannsgruber J.
        • Metz M.
        • Steigerwald S.
        • Flentje M.
        • et al.
        Patient-reported symptoms during radiotherapy.
        Strahlenther Onkol. 2017; 193: 570-577
        • Mauguen A.
        • Le Péchoux C.
        • Saunders M.I.
        • Schild S.E.
        • Turrisi A.T.
        • Baumann M.
        • et al.
        Hyperfractionated or accelerated radiotherapy in lung cancer: an individual patient data meta-analysis.
        J Clin Oncol. 2012; 30: 2788
        • Main C.
        • Dandapani M.
        • Pritchard M.
        • Dodds R.
        • Stevens S.P.
        • Thorp N.
        • et al.
        The effectiveness and safety of proton beam radiation therapy in children with malignant central nervous system (CNS) tumours: protocol for a systematic review.
        Syst Rev. 2016; 5: 124
        • Childs P.J.
        • Bidmead M.
        • Symonds P.
        • Deehan C.
        • Mills J.
        • Cathy M.
        Principles and practice of radiation treatment planning.
        in: Walter and Miller's Textbook of Radiotherapy: Radiation Physics, Therapy and Oncology. 7th ed. Elsevier Churchill Livingstone, Edinburgh2012: 159-188
        • Marbach J.
        • Sontag M.
        • Van Dyk J.
        • Wolbarst A.
        Management of radiation oncology patients with implanted cardiac pacemakers: report of AAPM Task Group No. 34.
        Med Phys. 1994; 21: 85-90
        • Gauter-Fleckenstein B.
        • Israel C.W.
        • Dorenkamp M.
        • Dunst J.
        • Roser M.
        • Schimpf R.
        • et al.
        DEGRO/DGK guideline for radiotherapy in patients with cardiac implantable electronic devices.
        Strahlenther Onkol. 2015; 191: 393-404
        • Fetahović I.
        • Pejović M.
        • Vujisić M.
        Radiation damage in electronic memory devices.
        Int J Photoenergy. 2013; 2013: 170269
        • Indik J.H.
        • Gimbel J.R.
        • Abe H.
        • Alkmim-Teixeira R.
        • Birgersdotter-Green U.
        • Clarke G.D.
        • et al.
        2017 HRS expert consensus statement on magnetic resonance imaging and radiation exposure in patients with cardiovascular implantable electronic devices.
        Heart Rhythm. 2017; 14: e97-e153
        • Hoecht S.
        • Rosenthal P.
        • Sancar D.
        • Behrens S.
        • Hinkelbein W.
        • Hoeller U.
        Implantable cardiac defibrillators may be damaged by radiation therapy.
        J Clin Oncol. 2002; 20: 2212-2213
        • Raitt M.H.
        • Stelzer K.J.
        • Laramore G.E.
        • Bardy G.H.
        • Dolack G.L.
        • Poole J.E.
        • et al.
        Runaway pacemaker during high-energy neutron radiation therapy.
        Chest. 1994; 106: 955-957
        • John J.
        • Kaye G.C.
        Shock coil failure secondary to external irradiation in a patient with implantable cardioverter defibrillator.
        Pacing Clin Electrophysiol. 2004; 27: 690-691
        • Hashii H.
        • Hashimoto T.
        • Okawa A.
        • Shida K.
        • Isobe T.
        • Hanmura M.
        • et al.
        Comparison of the effects of high-energy photon beam irradiation (10 and 18 MV) on 2 types of implantable cardioverter-defibrillators.
        Int J Radiat Oncol Biol Phys. 2013; 85: 840-845
        • Lau D.H.
        • Wilson L.
        • Stiles M.K.
        • John B.
        • Shashidhar
        • Dimitri H.
        • et al.
        Defibrillator reset by radiotherapy.
        Int J Cardiol. 2008; 130: e37-e38
        • Gelblum D.Y.
        • Amols H.
        Implanted cardiac defibrillator care in radiation oncology patient population.
        Int J Radiat Oncol Biol Phys. 2009; 73: 1525-1531
        • Soejima T.
        • Yoden E.
        • Nishimura Y.
        • Ono S.
        • Yoshida A.
        • Fukuda H.
        • et al.
        Radiation therapy in patients with implanted cardiac pacemakers and implantable cardioverter defibrillators: a prospective survey in Japan.
        J Radiat Res. 2011; 52: 516-521
        • Makkar A.
        • Prisciandaro J.
        • Agarwal S.
        • Lusk M.
        • Horwood L.
        • Moran J.
        • et al.
        Effect of radiation therapy on permanent pacemaker and implantable cardioverter-defibrillator function.
        Heart Rhythm. 2012; 9: 1964-1968
        • Venselaar J.L.
        The effects of ionizing radiation on eight cardiac pacemakers and the influence of electromagnetic interference from two linear accelerators.
        Radiother Oncol. 1985; 3: 81-87
        • Zaremba T.
        • Jakobsen A.R.
        • Søgaard M.
        • Thøgersen A.M.
        • Johansen M.B.
        • Madsen L.B.
        • et al.
        Risk of device malfunction in cancer patients with implantable cardiac device undergoing radiotherapy: a population-based cohort study.
        Pacing Clin Electrophysiol. 2015; 38: 343-356
        • Souliman S.K.
        • Christie J.
        Pacemaker failure induced by radiotherapy.
        Pacing Clin Electrophysiol. 1994; 17: 270-273
        • Elders J.
        • Kunze-Busch M.
        • Jan Smeenk R.
        • Smeets J.L.
        High incidence of implantable cardioverter defibrillator malfunctions during radiation therapy: neutrons as a probable cause of soft errors.
        Europace. 2013; 15: 60-65
        • Last A.
        Radiotherapy in patients with cardiac pacemakers.
        Br J Radiol. 1998; 71: 4-10
        • Hurkmans C.W.
        • Scheepers E.
        • Springorum B.G.
        • Uiterwaal H.
        Influence of radiotherapy on the latest generation of implantable cardioverter-defibrillators.
        Int J Radiat Oncol Biol Phys. 2005; 63: 282-289
        • Brooks C.
        • Mutter M.
        Pacemaker failure associated with therapeutic radiation.
        Am J Emerg Med. 1988; 6: 591-593
        • Mouton J.
        • Haug R.
        • Bridier A.
        • Dodinot B.
        • Eschwege F.
        Influence of high-energy photon beam irradiation on pacemaker operation.
        Phys Med Biol. 2002; 47: 2879
        • Mollerus M.
        • Naslund L.
        • Lipinski M.
        • Meyer A.
        • Libey B.
        • Dornfeld K.
        Radiation tolerance of contemporary implantable cardioverter-defibrillators.
        J Interv Card Electrophysiol. 2014; 39: 171-175
        • Uiterwaal G.
        • Springorum B.
        • Scheepers E.
        • De Ruiter G.
        • Hurkmans C.
        Interference detection in implantable defibrillators induced by therapeutic radiation therapy.
        Netherlands Heart J. 2006; 14: 330
        • Bradley P.
        • Normand E.
        Single event upsets in implantable cardioverter defibrillators.
        IEEE Trans Nucl Sci. 1998; 45: 2929-2940
      5. Kobayashi H. Shiraishi K. Tsuchiya H. Motoyoshi M. Usuki H. Nagai Y. Soft errors in SRAM devices induced by high energy neutrons, thermal neutrons and alpha particles. Digest International Electron Devices Meeting: IEEE, 2002
        • Gomez D.R.
        • Poenisch F.
        • Pinnix C.C.
        • Sheu T.
        • Chang J.Y.
        • Memon N.
        • et al.
        Malfunctions of implantable cardiac devices in patients receiving proton beam therapy: incidence and predictors.
        Int J Radiat Oncol Biol Phys. 2013; 87: 570-575
        • Grant J.D.
        • Jensen G.L.
        • Tang C.
        • Pollard J.M.
        • Kry S.F.
        • Krishnan S.
        • et al.
        Radiotherapy-induced malfunction in contemporary cardiovascular implantable electronic devices: clinical incidence and predictors.
        JAMA Oncol. 2015; 1: 624-632
        • Lin J.-P.
        • Chu T.-C.
        • Lin S.-Y.
        • Liu M.-T.
        The measurement of photoneutrons in the vicinity of a Siemens Primus linear accelerator.
        Appl Radiat Isot. 2001; 55: 315-321
        • Cardenas C.E.
        • Nitsch P.L.
        • Kudchadker R.J.
        • Howell R.M.
        • Kry S.F.
        Out-of-field doses and neutron dose equivalents for electron beams from modern Varian and Elekta linear accelerators.
        J Appl Clin Med Phys. 2016; 17: 442-455
        • McCollough C.H.
        • Zhang J.
        • Primak A.N.
        • Clement W.J.
        • Buysman J.R.
        Effects of CT irradiation on implantable cardiac rhythm management devices.
        Radiology. 2007; 243: 766-774
        • Solan A.N.
        • Solan M.J.
        • Bednarz G.
        • Goodkin M.B.
        Treatment of patients with cardiac pacemakers and implantable cardioverter-defibrillators during radiotherapy.
        Int J Radiat Oncol Biol Phys. 2004; 59: 897-904
        • Sundar S.
        • Symonds R.
        • Deehan C.
        Radiotherapy to patients with artificial cardiac pacemakers.
        Cancer Treat Rev. 2005; 31: 474-486
        • Lester J.F.
        • Evans L.M.
        • Yousef Z.
        • Penney A.
        • Brown P.
        • Perks R.
        A national audit of current cardiac device policies from radiotherapy centres across the UK.
        Clin Oncol. 2014; 26: 45-50
        • Gossman M.S.
        • Wilkinson J.D.
        • Mallick A.
        Treatment approach, delivery, and follow-up evaluation for cardiac rhythm disease management patients receiving radiation therapy: retrospective physician surveys including chart reviews at numerous centers.
        Med Dosim. 2014; 39: 320-324
        • eviQ
        Managementof patients with cardiac implantable electronic devices during radiation therapy simulation and treatment 2021.
        • Luca F.
        • Parrini I.
        • Cipolletta L.
        • Di Fusco S.
        • Rao C.
        • Iorio A.
        • et al.
        Radiotherapy and devices in cancer patients: what is new in clinical practice?.
        Int J Heart Rhythm. 2019; 4: 4-13
        • Gossman M.S.
        • Graves-Calhoun A.R.
        • Wilkinson J.D.
        Establishing radiation therapy treatment planning effects involving implantable pacemakers and implantable cardioverter-defibrillators.
        J Appl Clin Med Phys. 2010; 11: 33-45
        • Hurkmans C.W.
        • Knegjens J.L.
        • Oei B.S.
        • Maas A.J.
        • Uiterwaal G.
        • van der Borden A.J.
        • et al.
        Management of radiation oncology patients with a pacemaker or ICD: a new comprehensive practical guideline in The Netherlands.
        Radiat Oncol. 2012; 7: 1-10
      6. Monitoring patients with implanted cardiac rhythm devices receiving radiation therapy.
        Oncol Nurs Forum. 2009; 36: 629-632
        • Kry S.F.
        • Bednarz B.
        • Howell R.M.
        • Dauer L.
        • Followill D.
        • Klein E.
        • et al.
        Aapm TG 158: measurement and calculation of doses outside the treated volume from external-beam radiation therapy.
        Med Phys. 2017; 44: e391-e429
        • Hussein A.A.
        • Abutaleb A.
        • Jeudy J.
        • Phelan T.
        • Patel R.
        • Shkullaku M.
        • et al.
        Safety of computed tomography in patients with cardiac rhythm management devices: assessment of the US Food and Drug Administration advisory in clinical practice.
        J Am Coll Cardiol. 2014; 63: 1769-1775
        • Wadasadawala T.
        • Pandey A.
        • Agarwal J.
        • Jalali R.
        • Laskar S.
        • Chowdhary S.
        • et al.
        Radiation therapy with implanted cardiac pacemaker devices: a clinical and dosimetric analysis of patients and proposed precautions.
        Clinical Oncology. 2011; 23: 79-85